RAJ ANALYTICAL SERVICES A Leading Supplier of Chromatography Products
E-Mail info@rajanalytical.com
 
HOME ABOUT US PRODUCTS



IR/FTIR/XRF Supplies

Precision Weights

CLIENTS OUR PRINCIPALS DOWNLOADS CONTACTS US Request for a Quote
 
Standards
 
pH buffers
(Certified from an accredited laboratory. 5 -year stability and easy handling)

Features:
  • Convenient 250 mL and 500 mL plastic bottle with built-in calibration compartment
  • Economical, since only about 20 mL of buffer is used per calibration
  • Actual value is determined by a DKD laboratory, accredited for pH measurement
  • First class certificate with traceability to international standards
  • Expiration date on the bottle
  • Immune to micro-organisms
Buffers available with pH value
(1.09, 1.68, 2.00, 3.06, 4.01, 5,00, 6.00, 7.00, 8.00, 9.21, 10.1, 11, 12)
 
 
 
 
Conductivity standards
(Certified from an accredited laboratory. Fulfills USP chapter 625 requirements)

Unique Advantages:
  • Stable for at least 1 year (1.3 μS/cm), up to 3 years
  • Certified standards with traceable calibration from DFM
  • Expiration date on every bottle
  • First class certificate with traceability to international standards
  • Bottles can remain open for up to 60 minutes and retain the certified value.
Available standards
(1.3, 5,15, 84,100, 147, 1413, 12288 μS/cm)
 
 
 
 
Polymer Standards for GPC

Polymer standards are available in the widest range of molecular weights, and as kits and individual molecular weights for maximum choice.

Polymer standards are supplied with a comprehensive Certificate of Analysis detailing the characterization procedures employed and the results obtained.
 
 
Polymer Type Individual MW Calibration Kits EasiCal™ EasiVial™ Types of GPC/SEC
Polystyrene Yes Yes Yes Yes Organic
Polymethylmethacrylate Yes Yes - Yes Organic
Polyethylene Glycol (PEG) Yes Yes - Yes Organic/Aqueous
Polyethylene Oxide (PEO) Yes Yes - Yes Organic/Aqueous
Pullulan Polysaccharide Yes Yes - - Organic/Aqueous
Polyacrylic Acid (Na Salt) Yes Yes - - Aqueous
 
Polymer Standards available as
  • Calibration Kits:
    Polyacrylic Acid ( Na salt ) Kits, Polyethylene ( Linear ) Kits, Polyethylene ( Short Chain Branching ) Kits, Polyethylene Glycol ( PEG ) Kits, Polyethylene Oxide ( PEO ) Kits, Polymethylmethacrylate ( PMMA ) Kits, Polystyrene ( PS ) Kits, Pullulan Polysaccharide Kits

  • EasiCal Pre-prepared Calibration Kits:
    Polystyrene PS-1 (MW Range 580-7,500,000), Polystyrene PS-2 (MW Range 580-400,000)

  • EasiVial Pre-weighed Polymer Standards Kits
EasiVial Type EasiVial PS-H EasiVial PS-M EasiVial PS-L EEasiVial PM EasiVial PEG/PEO
Red Nominal Mp
6,000,000
500,000
20,000
1,300
3,000,000
Nominal Mp
400,000
50,000
6,000
780
200,000
Nominal Mp
40,000
10,000
3,000
580
25,000
Nominal Mp
2,000,000
300,000
30,000
2,000
800,000
Nominal Mp
1,200,000
125,000
12,000
600
1,000,000
Yellow 185,000
8,500
580
900,000
25,000
2,500
370
100,000
6,000
2,000
370
16,000
150,000
13,000
1,000
470,000
60,000
4,000
200
460,000
Green 60,000
3,400
162
11,000
1,500
162
4,000
1,000
162
80,000
5,700
600
25,000
1,500
100
  • Linear, Narrow Dispersity Polyethylene Standards:
    Polyethylene GPC Calibration Kit (E-MW-10) Kit Type E-MW-10 MW Range 5,000-1,500,000; Polyethylene GPC Calibration Kit (E-M-10) Kit Type E-M-10 MW Range 170-120,000

  • Nominals / Individual Molecular Weights:
    Polyacrylic Acid ( Na Salt ), Polyethylene, Polyethylene Glycol ( PEG ) , Polyethylene Oxide ( PEO ), Polymethylmethacrylate ( PMMA ), Polystyrene, Pullulan Polysaccharide

  • Specialty Polymers:
    Block Copolymers, Deuterated Polymethylmethacrylate -d8, Deuterated Polystyrene -d8, Methoxy Polyethylene Glycols (MPEGs)
 
Atomic Spectroscopy Standards
Wide Selection of Atomic Spectroscopy Calibration Standards are available. Each solution is supplied with comprehensive Certificate of Analysis.
  • Multi Element Standards
  • Spike Sample Analysis
  • Enviornmental Method Sets
  • Internal Standard Solutions
  • Performance Verification Standards
  • Instrument Calibration Standards
  • Instrument Check Standards
  • SmartTune Standards
  • Wash Standards
  • Single Element Calibration Standards
  • Mixed Calibration Standards
  • Initial Calibration Verification Standards
  • Contract Required Detection Limit (CRDL)
  • Quality Control Standards
  • WaveCal Solutions
  • Interference Check Standards
  • Water Pollutant Standards
In case you have any specific requirement, please contact us.
 
All respective trademarks acknowledged.
 
 
Product Catalog
Application Database
News & Events
Exhibition: Analytica Anacon 2009
Exhibition: Analytica Anacon 2009
View More Photos
Brands
Text will go here.
Did you know ?
 
Testimonials
Text will go here.
 
 
 
 
Home
About us
Products
Clients
Our Principals
CAREERS
Sitemap
Downloads
Contact us
© 2010 Raj Analytical Services, All Rights Reserved.
Follow Us
Twitter Facebook