Free Quote
Stay Informed of the latest news, products, special offers and more
+91 (0) 172 - 2210586
 

Solid Phase Extraction

SPE Vacuum Manifold

VacElut 20 Manifold

VacElut20

VacElut20

Corrosion-resistant VacElut 20 permits simultaneous processing of up to 20 SPE cartridges. The manifold’s clear glass base allows careful monitoring of the entire sample collection process.

The VacElut 20 vacuum control valve, vacuum gauge, and quick release valve are mounted on the lid, away from the corrosive solvent stream and within convenient reach.

VacElut SPS 24 Manifold

Flash Holder40

VacElut SPS24

  • The VacElut SPS 24 allows simultaneous processing of up to 24 SPE cartridges.
  • VacElut SPS 24 is made from durable, solvent-resistant materials and engineered
    to last.
  • The glass sides allow easy viewing of the entire sample collection process

The ultimate feature of the SPS 24 manifold is its waste diversion funnel, which enables all steps of the SPE procedure to be completed without removing the lid. Since the collection rack is placed inside the unit before extraction begins, splash back and cross contamination are eliminated, while hazardous waste and biohazard exposure are minimized.

Complete with replacement stainless steel delivery tips for maximum extract purity, the VacElutSPS 24 system also includes a vacuum controller/release, collection rack, and port sealing plugs.

Check Vacuum Pumps for Manifold.

SPE Columns Format

SPE Cartridges/Columns are available in various formats for varied applications.

CHROMABOND® polypropylene columns

Spe Filter Element

  • PP columns with PE filter elements
  • different sizes from 1, 3, 6 up to 150 ml
  • adsorbent weights from 20 mg to 50 g
  • male luer tip as exit
  • compatible with most robots (e. g. Gilson ASPEC™, Caliper AutoTrace®, …)

CHROMABOND®glass columns

  • glass columns with chemically very inert glass fibre filter elements (nominal pore size 1 µm)
  • two different sizes: 3 and 6 ml
  • available with all CHROMABOND® phases
  • excludes any influence from the column material (e. g. plasticizers, …)

CHROMAFIX®cartridges

Spe Filter Element

  • PP cartridges with PE filter elements
  • three different sizes with different adsorbent weights: Small (0.4 ml), Medium (0.8 ml), Large (1.8 ml)
  • female Luer tip at the inlet, male Luer tip as exit
  • offers alternative way of handling using positive
  • pressure by syringes or peristaltic pumps
  • especially suited for convenient solid phase extraction of small sample volumes

CHROMABOND®LV columns

Spe Filter Element

  • large volume PP columns with PE filter elements
  • three different adsorbent weights (100, 200 and 500 mg)
  • funnel-shaped reservoir with 15 ml volume
  • especially for clinical samples - the whole sample (e. g. urine, serum, blood) can be applied to the column in one step
  • can be directly used in the Zymate®lab robots of Zymark

CHROMABOND®MULTI 96 SPE in 96-well format

Spe Filter Element

  • 96-well polypropylene plates with PE filter elements
  • cavity volume 1.5 ml
  • adsorbent weights from 25 to 100 mg
  • supplied with any CHROMABOND® SPE adsorbents
  • for simultaneous preparation of 96 samples
  • easy method transfer from CHROMABOND®columns or CHROMAFIX® cartridges to CHROMABOND®MULTI 96

SPE Columns

SPE columns are available for

  • Reverse Phase
  • Normal Phase
  • Ion Exchange Phase
  • Phase for Special Applications

Reverse phases for SPE
Code Matrix Particle size Pore size Specification
HR-X PS/DVB 45 µm / 85 µm 55–60 Å spherical particles
EASY PS/DVB 80 µm 50 Å polar, bifunctional modification
HR-P PS/DVB 50–100 µm    
PS-RP PS/DVB 100 µm 100 Å for removal of organic components from water
C18 ec silica 45 µm 60 Å octadecyl modification, endcapped
C18 ec f silica 100 µm 60 Å as above, fast flow
C18 silica 45 µm 60 Å octadecyl modification, not endcapped
C18 f silica 100 µm 60 Å as above, fast flow
C18 PAH silica 45 µm 60 Å special octadecyl phase, for enrichment of PAHs from water
C18 Hydra silica 45 µm 60 Å octadecyl modification, not endcapped, for polar analytes
C8 silica 45 µm 60 Å octyl modification
C4 silica 45 µm 60 Å butyl modification
C2 silica 45 µm 60 Å dimethyl modification
C6H11 ec silica 45 µm 60 Å cyclohexyl modification, endcapped
C6H5 silica 45 µm 60 Å phenyl modification
Normal phases for SPE
Code Matrix Particle size Pore size Modification
SiOH silica 45 µm 60 Å unmodified
NH2 silica 45 µm 60 Å aminopropyl
OH (Diol) silica 45 µm 60 Å diol
CN silica 45 µm 60 Å cyano (nitrile)
Alox A aluminium oxide, acidic 60–150 µm    
Alox N aluminium oxide, neutral 60–150 µm    
Alox B aluminium oxide, basic 60–150 µm    
Florisil® magnesium silicate 150–250 μm    
PA polyamide 6 40–80 μm    
Ion exchange phases for SPE
Code Matrix Particle size Pore size Specification
HR-XC PS/DVB 45 µm / 85 µm 60 Å 65–75 Å benzenesulfonic acid modification, very strong mixed mode cation exchanger (MCX)
HR-XA PS/DVB 45 µm / 85 µm 55–65 Å quaternary ammonium modification, very strong mixed mode anion exchanger (MAX)
HR-XCW PS/DVB 45 µm / 85 µm 50–60 Å carboxylic acid modification, vweak mixed mode cation exchanger (WCX)
HR-XAW PS/DVB 45 µm / 85 µm 55–65 Å secondary and tertiary ammonium modification, weak mixed mode anion exchanger (WAX)
SA silica 60–150 µm 60 Å benzenesulfonic acid modification, strongly acidic cation exchanger (SCX)
SB silica 60–150 µm 60 Å quaternary ammonium modification, strongly basic anion exchanger (SAX)
PCA silica 45 μm 60 Å propylcarboxylic acid modification, weakly acid cation exchanger (WCX)
PSA silica 45 μm 60 Å propylsulfonic acid modification, very strong cation exchanger
PS-OH– PS/DVB 100 μm 100 Å PS/DVB anion exchanger, OH– form for removal or concentration of anions from water, increasing the pH value in acidic samples
PS-H+ PS/DVB 100 μm 100 Å PS/DVB cation exchanger, H+ form for removal or concentration of cations from water, decreasing the pH value of basic samples
PS-Mix PS/DVB 100 μm 100 Å mixture of PS-H+ and PS-OH– for desalting of water
PS-Ag+ PS/DVB 100 μm 100 Å PS/DVB cation exchanger, Ag+ form for removal of halide ions from water
PS-Ba2+ PS/DVB 100 μm 100 Å PS/DVB cation exchanger, Ba2+ form for removal of sulfate ions from water
SPE phases for special applications
CHROMABOND® Matrix Modification Application
Pharmaceutical analysis
Drug silica bifunctional, C8 / SA (strong cation exchanger, benzenesulfonic acid) acidic, neutral and basic drugs like opiates, amphetamines
Drug II silica bifunctional, C8 / SB (strong anion exchanger, quaternary amine) THC and THC derivatives, acidic analytes from biological fluids
Crosslinks cellulose   collagen crosslinks from urine
Tetracycline silica special C18 phase tetracyclines from biological samples
Environmental analysis
HR-P-AOX PS/DVB   AOX from waters with high salt loads (DIN 38409 - H22)
C18 PAH silica special octadecyl phase PAHs from water
CN/SiOH silica cyanopropyl silica and unmodified silica PAHs from soil acc. to EPA
NH2/C18 silica aminopropyl silica and octadecyl silica PAHs from water containing humic acids
Na2SO4/Florisil® sodium sulfate / Florisil® determination of hydrocarbons from water according to DIN H-53 / ISO DIS 9377-4
SA/SiOH silica strong cation exchanger and unmodified silica PCBs from waste oil
SiOH-H2SO4/SA silica sulfuric acid impregnated silica and strong cation exchanger PCBs from oil acc. to the german standard DIN 51527
NAN sodium sulfate (N) and SiOH/AgNO3 (A) PCBs from sludge
Food analysis
ABC18 silica octadecyl and ion exchange functions extraction of acrylamide from food
Diamino silica primary and secondary amine functions (PSA) pesticides in food by the QuEChERS method
QuEChERS silica QuEChERS mixes: individually weighed and premixed buffer and extraction mixtures, specially composed for different sample matrices pesticides in food by the QuEChERS method
Other special phases
Dry (Na2SO4) anhydrous sodium sulfate drying of organic solutions
XTR kieselguhr liquid-liquid extraction
PTL / PTS special membranes separation of two-phase mixtures without separation funnel

CHROMABOND®HR-Xpert

The innovative concept of five polymer-based RP and mixed-mode ion exchange phases for SPE:

dummy

dummy

  • CHROMABOND®HR-X hydrophobic PS/DVB copolymer
  • CHROMABOND®HR-XC strong mixed-mode cation exchanger
  • CHROMABOND®HR-XA strong mixed-mode anion exchanger
  • CHROMABOND®HR-XCW weak mixed-mode cation exchanger
  • CHROMABOND®HR-XAW weak mixed-mode anion exchanger

CHROMABOND®HR-Xpert is the perfect combination for all tasks in sample preparation

These innovative SPE phases offer:

state-of-the-art spherical polymer

  • broad spectrum of applications with special suitability for enrichment of pharmaceuticals from biological matrices
  • ideal flow properties due to low content of particulate matter

optimised pore structure and high specific surface

  • highloadability and outstanding elution properties
  • low solvent consumption
  • rapid, economical analyses

high-purityadsorber material

  • allows highest reproducibility with extremely low blind values
  • reliable analyses at ultra trace level
  • no method adaptation for new batches necessary

SPE Method Development Kits

SPE method development kits are available for

Chromabond Packages

Chromabond Packages

  • Investigating the best separation mechanism for a clean-up procedure
  • Selecting the optimum RP phase for clean-up procedure
  • Selecting the optimum polar phase for a clean-up procedure
  • Selecting the optimum ion exchange for a clean-up procedure
  • Phase selection for clean-up procedures for environmental samples.

Automated and on-line SPE

  • Ready-to-use EC columns or ChromCart® cartridges for online-SPE Standard dimensions 20 x 2 mm and 20 x 4 mm Packed with CHROMABOND® HR-Xpert phases (15 µm particles) or with NUCLEODUR® C18 ec, C8 ec, CN (20 µm particles)
  • Special SPE columns already equipped with special caps and needles to be used in the SPE unit of theGerstel MultiPurposeSampler (MPS), available in 1, 3 and 6 mL
  • Columns for Gilson ASPEC™ systems are ready-to-use assembled with caps. In addition to the columns and phases, all 1, 3 and 6 mL CHROMABOND® polypropylene columns can be supplied assembled with ASP caps.
EC columns

EC columns

CC columns

CC columns

SPE cartridges for the Gerstel MPS system

SPE cartridges for the Gerstel MPS system

The Gerstel MPS system

The Gerstel MPS system

STAY CONNECTED

RECEIVE OUR NEWSLETTER